Partial SRF HCO of 2L26
2L26:
Bay 4 not making it to HV. (Cav. 6/8)
2L26-1 drops zone from HV on high reflected power
ARCs: All 8 arc detectors okay.
IRs:
-Cold test: Cav. 1 non-responsive; cav. 7 responding wrong direction when cold window test actuated. All 8 channels trigger FSD when trip set point below readback.
-Warm test: All 8 warm window test driving voltage down, not up.
Raised Liquid Level set point to 92% at 2L25
QuickPic - 2L26-1 drops zone from HV
Warm window test function responding backwards on 2L26
APPROVED seal lintel and door maintenance
2L26-7 cold window test function responding wrong direction
QuickPic - 2L26-1 cold window test function non-responsive
COMMENT ON SRI3C12 Alignment
Heater config 2L25 for Qo's
North Linac Dropping to Lockdown
At 01:45 last night, the NL dropped to Restricted Lockdown. The iFix alarms panel shows the reason was the personnel door was opened for Exit Stair 1. Checking the door status, it shows the ES1 doors were made up.
I went out to ES1 to check and I didn't see any personnel or vehicles, and the door maglites were illuminated.
When the guards dropped off the door check, it shows that Exit Stair 1 was checked at 01:45. The guards don't have a way to unlock that door, so I'm assuming the door was physically jostled to verify that it was locked, causing the NL to drop to lockdown.
2L26 Bay 4 not making it to HV
Program Deputy Summary, presented 2026-04-23
Operator SIGN IN
COMMENT ON Measure photocathode analyzing power at high voltage
Photocathode Anisotropy Measurements:
https://logbooks.jlab.org/entry/4490439
COMMENT ON MOLLER Beam Study: Wien Flip Symmetry Measurement
MOLLER Wien symmetry tests:
https://logbooks.jlab.org/entry/4490459
HDR AM WALKS
Follow-up Re: Water Barrel under Injector Penetration is about one-third full
Backing out of 2L25 Flow Meter measurements
COMMENT ON Q0 Measurements via Flow Meter on Zone 2L25
Came in and started ramping cryo heaters down. After the slow ramp down, I calibrated the meter to be within tolerance. Initial Calibrations took some time, however, now that it's done it should not need to be redone for the rest of this measurement. I began taking cavity dissipation measurements around 2:30 am. Below are some rough results. More precise results will follow after analyzing the data in detail. However, for now, the below results should suffice. The remaining cavities will be measured tomorrow.