HYST AREA 7-0 Cycles Magnets

6 days 18 hours ago
Log Number: 4510824Logbook(s): Body: 

HYST AREA Version 7-0 has successfully cycled the following:

Area.Linacs.North
Area.Linacs.South
Area.Arcs.Arc1.Spreader
Area.Arcs.Arc1.Arc
Area.Arcs.Arc1.Recombiner
Area.Arcs.Arc1.Extraction
Area.Arcs.Arc2.Spreader
Area.Arcs.Arc2.Arc
Area.Arcs.Arc2.Recombiner
Area.Arcs.Arc2.Extraction
Area.Arcs.Arc3.Spreader
Area.Arcs.Arc3.Arc
Area.Arcs.Arc3.Recombiner
Area.Arcs.Arc3.Extraction
Area.Arcs.Arc4.Spreader
Area.Arcs.Arc4.Arc
Area.Arcs.Arc4.Recombiner
Area.Arcs.Arc4.Extraction
bschauml

Box Supplies Were Cycled

6 days 18 hours ago
Log Number: 4510823Logbook(s): Tags: Body: 

The following box supplies were CYCLED by version 2-16 of the Box Supply Cycling Script:
ARC1A Ramp Rate = 4.196 A/s
ARC2A Ramp Rate = 6.808 A/s
ARC3A Ramp Rate = 9.725 A/s
ARC4A Ramp Rate = 11.344 A/s
ARC5A Ramp Rate = 9.961 A/s
ARC6A Ramp Rate = 9.235 A/s
ARC7A Ramp Rate = 9.981 A/s
ARC8A Ramp Rate = 11.974 A/s
ARC9A Ramp Rate = 9.380 A/s
ARCAA Ramp Rate = 12.276 A/s
LAM1C Ramp Rate = 8.295 A/s
LAM3C Ramp Rate = 10.061 A/s
RSEP8A Ramp Rate = 10.612 A/s
RSEP9A Ramp Rate = 5.026 A/s

bschauml

Box Supplies Were Turned on at Setpoint 1

6 days 19 hours ago
Log Number: 4510820Logbook(s): Tags: Body: 

The following box supplies were TURNED ON AT SET POINT 1 by version 2-16 of the Box Supply Cycling Script:
ARC1A Ramp Rate = 7.954 A/s
ARC2A Ramp Rate = 6.939 A/s
ARC3A Ramp Rate = 9.377 A/s
ARC4A Ramp Rate = 10.989 A/s
ARC5A Ramp Rate = 9.739 A/s
ARC6A Ramp Rate = 9.235 A/s
ARC7A Ramp Rate = 9.981 A/s
ARC8A Ramp Rate = 11.974 A/s
ARC9A Ramp Rate = 9.216 A/s
ARCAA Ramp Rate = 12.276 A/s
DOG1E Ramp Rate = 4.178 A/s
DOG2E Ramp Rate N/A
DOG3E Ramp Rate N/A
DOG4E Ramp Rate N/A
DOG5E Ramp Rate N/A
DOG6E Ramp Rate N/A
DOG7E Ramp Rate N/A
DOG8E Ramp Rate N/A
DOG9E Ramp Rate

bschauml

Downtime Incident CLOSED: 1L21-4 OLT

6 days 19 hours ago
Log Number: 4510819Logbook(s): Body: IDDescriptionPeriodCause 17166Title:
1L21-4 OLT

Summary:
Cavity was repeatedly opening the RF switch while attempting an OLT. RF on-call attempted to resolve it remotely but, after some troubleshooting, the zone would not recover HV.
eforman

1L21-4 BLVF/FSD preventing HV

6 days 19 hours ago
Log Number: 4510816Logbook(s): Entry Makers: kernsBody: 

Dropped zone to null after several attempts to turn cav4 on with instant drop back once in HV. Reset after reboot of cav 4 but zone wouldn't even attempt to go into HV after all back into filaments. Noticed that filaments were all low after complete filament counts. Came onsite and didn't see anything at all so I cycled the CPS a/c overcurrent and control power and successfully got zone back into HV and RF. Restored Cav 4 to ODVH= 8.9 Mv/m. Checked out cav. 7 and it does have low drive out but will have to check RFCM out before I can say it's a 2.5w amp. Handing back to OPS.

kerns