Aggregator
HYST AREA 7-0 Cycles Magnets for LEM
LEM North Linac
The OPS DRVHs for the following cavities have been updated: 1L23-1
The OPS DRVHs for the following cavities have been updated:
1L23-1
Username: bschauml
Date/Time: 06-11-26_19:43:52
RF Status: Good
Tuner Status: Good
Comment: DRVH=11.300 Quenching
Previous OPS DRVH: 11.5
Special Instructions: Faults evenly spaced
Downtime Incident CLOSED: Multiple trim cards in 3 different adjacent racks mismatched
Multiple trim cards in 3 different adjacent racks mismatched
Downtime Incident CREATED: Multiple trim cards in 3 different adjacent racks mismatched
MBC7R08V mismatch
MQD1L02 & MQD0R05 Mismatching
HYST AREA 7-0 Cycles Magnets
HYST AREA Version 7-0 has successfully cycled the following:
Area.Linacs.North
Area.Linacs.South
Area.Arcs.Arc1.Spreader
Area.Arcs.Arc1.Arc
Area.Arcs.Arc1.Recombiner
Area.Arcs.Arc1.Extraction
Area.Arcs.Arc2.Spreader
Area.Arcs.Arc2.Arc
Area.Arcs.Arc2.Recombiner
Area.Arcs.Arc2.Extraction
Area.Arcs.Arc3.Spreader
Area.Arcs.Arc3.Arc
Area.Arcs.Arc3.Recombiner
Area.Arcs.Arc3.Extraction
Area.Arcs.Arc4.Spreader
Area.Arcs.Arc4.Arc
Area.Arcs.Arc4.Recombiner
Area.Arcs.Arc4.Extraction
Box Supplies Were Cycled
The following box supplies were CYCLED by version 2-16 of the Box Supply Cycling Script:
ARC1A Ramp Rate = 4.196 A/s
ARC2A Ramp Rate = 6.808 A/s
ARC3A Ramp Rate = 9.725 A/s
ARC4A Ramp Rate = 11.344 A/s
ARC5A Ramp Rate = 9.961 A/s
ARC6A Ramp Rate = 9.235 A/s
ARC7A Ramp Rate = 9.981 A/s
ARC8A Ramp Rate = 11.974 A/s
ARC9A Ramp Rate = 9.380 A/s
ARCAA Ramp Rate = 12.276 A/s
LAM1C Ramp Rate = 8.295 A/s
LAM3C Ramp Rate = 10.061 A/s
RSEP8A Ramp Rate = 10.612 A/s
RSEP9A Ramp Rate = 5.026 A/s
HYST AREA 7-0 Cycles Magnets for LEM
LEM North Linac
Box Supplies Were Turned on at Setpoint 1
The following box supplies were TURNED ON AT SET POINT 1 by version 2-16 of the Box Supply Cycling Script:
ARC1A Ramp Rate = 7.954 A/s
ARC2A Ramp Rate = 6.939 A/s
ARC3A Ramp Rate = 9.377 A/s
ARC4A Ramp Rate = 10.989 A/s
ARC5A Ramp Rate = 9.739 A/s
ARC6A Ramp Rate = 9.235 A/s
ARC7A Ramp Rate = 9.981 A/s
ARC8A Ramp Rate = 11.974 A/s
ARC9A Ramp Rate = 9.216 A/s
ARCAA Ramp Rate = 12.276 A/s
DOG1E Ramp Rate = 4.178 A/s
DOG2E Ramp Rate N/A
DOG3E Ramp Rate N/A
DOG4E Ramp Rate N/A
DOG5E Ramp Rate N/A
DOG6E Ramp Rate N/A
DOG7E Ramp Rate N/A
DOG8E Ramp Rate N/A
DOG9E Ramp Rate
Downtime Incident CLOSED: 1L21-4 OLT
Downtime Incident CLOSED: Building 40 (W4) temperature exceeds 88 F
Downtime Incident CLOSED: Building 39 (E2) temperature exceeds 88 F
Downtime Incident CREATED: Building 40 (W4) temperature exceeds 88 F
1L21-4 BLVF/FSD preventing HV
Dropped zone to null after several attempts to turn cav4 on with instant drop back once in HV. Reset after reboot of cav 4 but zone wouldn't even attempt to go into HV after all back into filaments. Noticed that filaments were all low after complete filament counts. Came onsite and didn't see anything at all so I cycled the CPS a/c overcurrent and control power and successfully got zone back into HV and RF. Restored Cav 4 to ODVH= 8.9 Mv/m. Checked out cav. 7 and it does have low drive out but will have to check RFCM out before I can say it's a 2.5w amp. Handing back to OPS.