Aggregator
1L21-4 BLVF/FSD preventing HV
Dropped zone to null after several attempts to turn cav4 on with instant drop back once in HV. Reset after reboot of cav 4 but zone wouldn't even attempt to go into HV after all back into filaments. Noticed that filaments were all low after complete filament counts. Came onsite and didn't see anything at all so I cycled the CPS a/c overcurrent and control power and successfully got zone back into HV and RF. Restored Cav 4 to ODVH= 8.9 Mv/m. Checked out cav. 7 and it does have low drive out but will have to check RFCM out before I can say it's a 2.5w amp. Handing back to OPS.
Downtime Incident CREATED: Building 39 (E2) temperature exceeds 88 F
The following cavity histories have been updated: 1L09-2
The following cavity histories have been updated:
1L09-2
Username: yoon
Date/Time: 06-11-26_18:54:06
RF Status: Bad
Tuner Status: Good
Comment: C75 Bypassed - raising the mod anode voltage did not fix the mod anode current high fault this cavity is having
Special Instructions:
Maintenance Tag: Component: Other
1L09 zone dropped HV after bringing cavity 2 back up
tried to bring cavity 2 back up (from bypass) after RF increased the mod anode voltage, but cavity still tripping on mod anode current high fault, brought the zone out of HV and I'm unable to recover it, so going to re-bypass this cavity
The following cavity histories have been updated: 1L09-2
The following cavity histories have been updated:
1L09-2
Username: yoon
Date/Time: 06-11-26_18:45:54
RF Status: Good
Tuner Status: Good
Comment: C75 Unbypassed - mod anode voltage has been raised
Special Instructions:
Maintenance Tag: Component: Other
"Weekly MCC source checks complete"
Down due to RF, ramping down box supplies to reduce building heat load
Currently down due to 1L21-4 keeping the zone out of HV. RF on call is enroute and estimates that it could be several hours to swap out an RFCM. We are ramping down the box supplies to reduce the heat load in the buildings with temperature alarms (Facilities is supposed to be addressing that problem but we haven't had an update yet). Fig. 1: building temperatures (red horizontal line is 88 degrees F).
We took a ZPOS before things went sideways, so (fingers crossed) we shouldn't have too much difficulty getting orbits back to where we were.
Box Supplies Were Turned Off
The following box supplies were TURNED OFF by version 2-16 of the Box Supply Cycling Script:
ARC1A Ramp Rate = 7.954 A/s
ARC2A Ramp Rate = 7.217 A/s
ARC3A Ramp Rate = 10.099 A/s
ARC4A Ramp Rate = 11.344 A/s
ARC5A Ramp Rate = 10.435 A/s
ARC6A Ramp Rate = 9.571 A/s
ARC7A Ramp Rate = 10.231 A/s
ARC8A Ramp Rate = 12.289 A/s
ARC9A Ramp Rate = 9.911 A/s
ARCAA Ramp Rate = 12.626 A/s
DOG1E Ramp Rate = 3.809 A/s
DOG2E Ramp Rate N/A
DOG3E Ramp Rate N/A
DOG4E Ramp Rate N/A
DOG5E Ramp Rate N/A
DOG6E Ramp Rate N/A
DOG7E Ramp Rate N/A
DOG8E Ramp Rate N/A
DOG9E Ramp Rate N/A
LAM1C
Downtime Incident CLOSED: 1L09-2 Bypass
Bypassing 1L09-2
The following cavity histories have been updated: 1L09-2
The following cavity histories have been updated:
1L09-2
Username: yoon
Date/Time: 06-11-26_18:08:53
RF Status: Bad
Tuner Status: Good
Comment: C75 Bypassed - cavity caused zone to drop out of HV twice
Special Instructions:
Maintenance Tag: Component: Other
COMMENT ON Install Temporary Air Conditioning Units
ATLis Comments Daily Digest
QuickPic - Tons of RF Trips in the NL
Downtime Incident CREATED: 1L21-4 OLT
Downtime Incident CLOSED: 1L09 Dropped HV
HYST AREA 7-0 Cycles Magnets
HYST AREA Version 7-0 has successfully cycled the following:
Area.Arcs.Arc1.Spreader
Area.Arcs.Arc1.Arc
Area.Arcs.Arc1.Recombiner
Area.Arcs.Arc1.Extraction
MBT1R01H
MBT1R02V
MBT1R03H
MBT1R04V
MBT1R06H
MBT1R07V
MBT1R09H
MBT1R10H
MBT1R10V
Total Time: 3.200 mins
Software On-Call
Contacted by Software On-Call for assistance with iocsoftslminj. Communication from the softIOC had stopped working with the GigE Camera. Most likely do to radiation. Used the Remote Camera Reboot Procedure from the OPS Image Management page to cycle power on the INJ slm. IOC resumed communication with the camera after the power cycle and the softIOC is back up.
Box Supplies Were Cycled
The following box supplies were CYCLED by version 2-16 of the Box Supply Cycling Script:
ARC1A Ramp Rate = 7.954 A/s
ARC3A Ramp Rate = 9.725 A/s
ARC5A Ramp Rate = 9.961 A/s
ARC7A Ramp Rate = 10.231 A/s
ARC9A Ramp Rate = 9.380 A/s
RSEP9A Ramp Rate = 5.058 A/s