ODH 207 Alarm
Log Number: 4503662Logbook(s): Entry Makers: janakBody:
Two operators responded to ODH 207 Alarm in the LERF Vault. When we got to the building there were no audible or visual alarms. We contacted the Crew Chief and he informed us the sensor was back to reading normal levels. We surveyed the area around the sensor anyway and our personal sensors read normal levels. We'll monitor for further faults but are not bypassing it at this time.
Follow-up Re: Follow-up Re: Scan result for TAGH:A:2:scaler_r1_vs_ HD:GONI:Y.RBV_vs_ HD:GONI:X.RBV
Follow-up Re: Hall C cryo return pressure dropping
Log Number: 4503648Logbook(s): Entry Makers: brendanwBody:
The CPI9541 transducer is unreliable. This transducer is upstream of the valve in the valve box, the CPI674 transducer is downstream of the valve, and the CPI61033 transducer is downstream of that, in the ESR2 coldbox. These pressures do not follow the drop in CPI9541.