QuickPic - Hall D -> 25 nA on diamond radiator
iCalibrate: Hall D
1L09-2 POFF Optimization
QuickPic - 1L07-8 POFF optimization
QuickPic - xC 60uA on Loop 2
iCalibrate: Hall C
AutoLog - UNMasking Hall C Normal Target
xC resuming current increase
Negative gDsRt values in INX1L24, 1L25, 1L06
Negative photon dose rate values in the NDX detectors happen typically when there's a real radiation event, but HV is not supplied. Case of NL24 and NL25: for some reason, their HV readback is zero, and in the brief moments of a beam loss in the area the neighboring NDXs do see a normal response, but NL24 and NL25 are negative. The HV value for their I400 electrometer needs to be recovered. The intermittent case of 1L06 is not clear. HV is ON there. The events do not seem to be real radiation as there's no correlated neighbors' response. Cable contacts?
xB requested decrease Halo trip limits
AutoLog - Masking Hall C Normal Target
AutoLog - Masking Hall C Normal Target
QuickPic - Hall D: 25 nA CW/ 1.1x 10-3 Al 100um
"Hall C: requests 40 uA"
"Hall C: requests 30 uA"
Downtime Incident CLOSED: Hall C: SHMS Troubleshooting
QuickPic - Hall C: Full Survey
iCalibrate: Hall C
xC Carbon 3% current ramp
Including all current changes for xC incremental current ramp up.
08:14 -> 2uA
08:45 -> 3uA
08:50 -> 4uA
08:53 -> 5uA
08:58 -> 6uA
09:00 -> 7uA
09:05 -> 10uA
09:09 -> 15uA
09:17 -> 20uA
09:22 -> 25uA
At about 9:25 the hall made an access for SHMS troubleshooting.