HALLC=>BCM=>IBC3H05=>IBC3H05:bcmtctemp_r (IBC3H05 Cavity Temperature) has been disabled in alarm handler
QuickPic - MBDAR02V mismatch - took setpoint - cycled
QuickPic - ODH head OM226 (LERF light room) bypassed & Light Room posted as ODH2
QuickPic - xB target change --> H2
QuickPic - Touched injector steering to lower A2 & A3 interception
"xB emptying target"
Downtime Incident CLOSED: MBC4R06H mismatch
Downtime Incident CLOSED: Pass3 RF separator tripped
Downtime Incident CREATED: Pass3 RF separator tripped
Pass 3 RF Separator recovered
A phone call was placed to Araiza - SSG
QuickPic - Pass 3 RF separator tripped off
Downtime Incident CREATED: MBC4R06H mismatch
MBC4R06H mismatch again
Hall B reached current setpoint, Attenuator continues to climb, INJ interception is soaking it up like a sponge
After Hall B, Hall C, & Hall D all reached current setpoints...
Hall B's Attenuator was at ~490
A3 interception was at ~0.075
But Hall B's attenuator continues to climb by +205 with no change in Hall B's current at 2C24
INJ interception is just soaking it up like a sponge until it trips
SHIFT UPDATE: Reloaded owl shift allsave, halls back to full requested current
Day shift was having considerable difficulty with beam loss in the 5E region and elevated halo rates in Hall B at passdown.
After a bit of poking around and investigating setpoint changes around the machine using ReCap, I loaded the all-save from the beginning of Owl shift last night.
Corrected pathlength, linac gang phases crested, and allowed the orbit locks to converge to the hall dumplettes (C beam for passes 1 through 3, D beam for the higher passes).
Brought halls up to requested current one-at-a-time starting with C, then B, and finally D.
All three halls are now receiving their req