Aggregator
1L25 BLVF
QuickPic - xC target change from Loop 2 to 10 cm Dummy at 40 uA, raster 2 mm by 2 mm
AutoLog - UNMasking Hall C Normal Target
iCalibrate: Hall C
"xC BNR for target change"
AutoLog - Masking Hall C Normal Target
Operator SIGN IN
Operator SIGN IN
Autolog save
Operator SIGN IN
smartRAT Cavity Instability Detection Daily Report
To view waveforms from a timestamp:
ssh opsrfdaqnl1 "smartRAT -m DAQ -d /data/fast_daq/<timestamp>"
To view waveforms of the top 25 from this report:
ssh opsrfdaqnl1 "smartRAT_view_daily_top25 2026-06-13-2026-06-20"
Data directory: /cs/prohome/apps/s/smartRAT2/3-4/fileio/pca_data/output_cavityOutDet/calibrated_cavitylevel_centralize_tsfresh_minimal_gmespmes/whole/rcntnp/2026-06-13-2026-06-20/PCA/
CREW CHIEF SIGN IN
THOMAS JEFFERSON NATIONAL ACCELERATOR FACILITY
ACCELERATOR OPERATIONS CREW CHIEF SIGN IN FORM
Date : 06-20-26
Time : 23:16:39
Day : Saturday
Shift : Owl
Crew Chief : Price
Program Deputy: Nissen
Team : D
Arm : Christian
Designated SSO: Chaudhary
LERF Operator:
Operators : Howard, Chaudhary, Christian
This stamp certifies that the above Crew Chief has read/reviewed/received the following:
Crew Chief Shift Log, 2026-06-20 SWING
Start of shift: Beam to Halls B & C
Crew Chief Timesheet Summary: 20 Jun 2026 SWING
1L20-4 Comm issue and faults
Wanted to post a follow up to Ben's ELOG 4514338 but the MyaPlot of 1L20-4 problem would attach for some reason so I'll use Jeli with a screen grab :
Can't have gradient if the zone isn't in HV. KCCU and GMES were still indicating after HV dropped at 1750. This is a latched gradient measured fault and should have cleared except the RFCM lost comm. Couldn't clear until comm's restored after a long reboot which it eventually did after I got remote screens up !!
1L20-4 Dropped Zone out of HV with Comm Watchdog
Watchdog fault was most likely caused by drop in HV at 1751 when all but cavity 4's KCCU went to 0.0 a except cavity 4's . Cavity 4's GMES and KCCU where still indicating until 1828 which is when Sam Holben oncall rebooted the RFCM per my instruction to clear the Watchdog faults that where stuck !! After it didn't recover comm. per Sam, Sam instructed OPS to try to bypass the cavity but this didn't clear the fault or allow the zone to go into filaments.
The OPS DRVHs for the following cavities have been updated: 1L20-3
The OPS DRVHs for the following cavities have been updated:
1L20-3
Username: benesch
Date/Time: 06-20-26_19:21:30
RF Status: Good
Tuner Status: Good
Comment: DRVH=3.300 Arc Rate Management five arc-only at 3.4, equally spaced
Previous OPS DRVH: 3.4
Special Instructions:
The OPS DRVHs for the following cavities have been updated: 2L12-4
The OPS DRVHs for the following cavities have been updated:
2L12-4
Username: benesch
Date/Time: 06-20-26_19:20:16
RF Status: Good
Tuner Status: Good
Comment: DRVH=5.600 Arc Rate Management four at 5.75, equally spaced
Previous OPS DRVH: 5.75
Special Instructions:
The OPS DRVHs for the following cavities have been updated: 2L08-4
The OPS DRVHs for the following cavities have been updated:
2L08-4
Username: benesch
Date/Time: 06-20-26_19:19:22
RF Status: Good
Tuner Status: Good
Comment: DRVH=7.400 Arc Rate Management one each at 7.1 and 7.47, two at 7.61
Previous OPS DRVH: 0
Special Instructions: