Beam loss in Injector - 17 uA are unaccounted for
With 60 uA from the Gun, 30 uA make it to the Halls, 13 uA are lost on Apertures (A1, A2, MS, and A3). The remaining 17 uA are unaccounted for. Maybe lost at the entrance of HWien.
Checking vacuum, it's hard to see where the beam loss is. But this is a baked beamline, this could be one reason.
MQD9S02 Mismatching, card replaced
Program Deputy Summary, presented 2024-04-24
Operator In Training SIGN IN
Operator SIGN IN
Operator SIGN IN
Crew Chief Shift Log, 2024-04-23 SWING
Start of shift:
CREW CHIEF SIGN IN
THOMAS JEFFERSON NATIONAL ACCELERATOR FACILITY
ACCELERATOR OPERATIONS CREW CHIEF SIGN IN FORM
Date : 04-24-24
Time : 07:28:26
Day : Wednesday
Shift : Day
Crew Chief : Richardson
Program Deputy: Gal
Team : X
Arm : Blackshaw
Designated SSO: Schoene
LERF Operator:
Operators : Blackshaw, Schoene, Shenenberger
This stamp certifies that the above Crew Chief has read/reviewed/received the following:
Hall B Halo Counters Limits adjusted for production
Hall B attenuator at 500 (70nA) with high Inj interceptions
Crew Chief Shift Log, 2024-04-24 OWL
Start of shift: Continuation of 4th pass setup to Hall C.
Crew Chief Timesheet Summary: 24 Apr 2024 OWL
Operator SIGN IN
Update
*Beam to Halls A, B, and C.
*Wien angle changed earlier today from 0deg to -39deg. Hall C did a pass change from 3 to 4.
*Injector ioc issues with in3 showing unresolved in alarm handler but all elements attached to the ioc produce legit readbacks.
Attempting to get 30 uA to xC
When trying to do an ion chamber calibration to xC up to 30 uA (production up to 40 uA on this target) we started getting instantaneous loss BLA trips at 22 uA and ILM4D00 trips. ILM3C12A was also elevated but not causing any trips at the time. I believe it would become an issue before the hall got up to 40 uA.
Started off nudging NL gang phase a bit to see if I could reduce the activity at ILM4D00, which was a bit successful. This also helped reduced ILM3C12A.