COMMENT ON Setup injector with 140kV gun for Spring 2026 Run
COMMENT ON Relocate B38 & B67 RTU thermostats
1D dipole (MBO0I06) setpoint for 140 kV operations
Looked back at the 2024 run when we were running a 140 kV Gun to see what the MBO0I06 dipole was set at for 1D running.
Looks to be 298 mA.
The dipole setting now for 200 kV is 372 mA.
The button / control screen Ops uses to set this magnet will need to be updated for that value. Perhaps we should also add in another row on the table for this energy and dipole current.
Reconfigured gun HVPS interlocks for beam ops
Following our weekend gun high voltage repair and testing, today we removed the J6 jumper which permitted the HVPS to enable with the gun vacuum valve closed. I removed the corresponding ABIL entry as well.
We are again in a normal gun HVPS interlock configuration. For example, with the gun valve closed we no longer hve a Global Vac/Valve permissive.
ABIL tag #9449 on HVPS MPS interlock (valve, dipole, SF6) has been removed
COMMENT ON Change-out VIPAD00C in Hall D Tagger Dump
2L13-1 No filament volts after Un-bypassed
The following cavity histories have been updated: 2L13-1
The following cavity histories have been updated:
2L13-1
Username: kerns
Date/Time: 03-09-26_12:13:03
RF Status: Bad
Tuner Status: Good
Comment: No filament voltage. Needs filament board replaced.
Special Instructions:
Maintenance Tag: Component: Filament Board
BEM daemon optics were resampled
Deployment: ced
Workspace: ops
Changes:
ipm0i01.alphax
ipm0i01.betax
ipm0i01.etax
ipm0i01.psix