Crew Chief Shift Log, 2026-06-06 OWL
Start of shift: Degrader beam studies in progress.
Crew Chief Timesheet Summary: 06 Jun 2026 OWL
I am suspicious of the central plug and/or C slit
Fig 1 shows that master slit interception is very very slightly higher when the central plug is *retracted*. The location of the central plug should have no bearing on MS interception at all. I could believe in the possibility of it seeing a hint of backscatter from the central plug when it's inserted but this seems to show the opposite, if only very slightly.
The angles of the central plug and C slit wrt y also make me suspicious.
CREW CHIEF SIGN IN
THOMAS JEFFERSON NATIONAL ACCELERATOR FACILITY
ACCELERATOR OPERATIONS CREW CHIEF SIGN IN FORM
Date : 06-06-26
Time : 08:02:19
Day : Saturday
Shift : Day
Crew Chief : Blackshaw
Program Deputy: Moser
Team : E
Arm : Chaudhary
Designated SSO: Janak
LERF Operator:
Operators : Chaudhary, Janak
This stamp certifies that the above Crew Chief has read/reviewed/received the following:
Finished beam study - Inj charge/discharge
Previous test ran to FC#1
Today's test ran to FC#2
Fig. 1 - Previous test
Fig. 2 - Today's test (interception)
Fig. 3 - Today's test (positions)
Fig. 4 - Another look from previous test and today's test
- CC Noticed when central plug is taken out, master slit interception increases
- Gun uA sags throughout (as opposed to Fig.1 where previous test shows gun uA having more of a 'wave' like pattern
- Noticed a separation drift between IPM2I00A (X vs Y)
- Previous test A1 interception steady. Today's test A1 interception starts low then rises
- Previous test Laser Hut Temp steady.
2L05-8 caused BLVF in 2L05 and 2L06 when recovering after FE Onset
This occurred twice when ramping gradient in 2L05-8 in SEL. The first time VBV2L05B and both VBV2L06A and VBV2L06B closed, dropping RF in both zones. The second time, only VBV2L05B and VBV2L06A closed, dropping RF in 2L05.
No response in 2L05-8 WG Vac. Can see a response in 2L06 beamline vac.
Was able to recover it into SELAP at 12.0 then walk it back up to its ODVH of 16.8 without any issue.
MBC4A27H - mismatch - reseed & took setpoint
COMMENT ON Post SAM FE onset measurements C75 and C100 cryomodules
FE Onset Measurements for 2L03: https://logbooks.jlab.org/entry/4508981
Operator SIGN IN
Field Emission Onset Measurements for 2L03
Powered on DRADS05A.
Figure 3, Cav 1: FE Free up to 21 MV/m.
Figure 4, Cav 2: FE Free up to 21 MV/m.
Figure 5, Cav 3: FE Free up to 20.5 MV/m. Slight amount of FE starting at 20.5, but still below the FE Onset of 10 mRem/hr at 21 MV/m.
Figure 6, Cav 4: FE Onset at 18.5 MV/m
Figure 7, Cav 5: FE Onset at 18.5 MV/m
Figure 8, Cav 6: FE Onset at 17.7 MV/m
Figure 9, Cav 7: FE Free up to 21 MV/m
Figure 10, Cav 8: FE Onset at 13.5 MV/m. Cavity 8 limited to 18.8 MV/m. Was getting quench faults, so I masked the quench bits and tried to push it beyond 18.8, but the GMES readback seemed to saturate.
Resuming beam study - Inj charge/discharge
https://tasklists.jlab.org/bslist/tasks/120407
Fig. 1 - positions
Fig. 2 - some light steering back to RELs beforehand
Fig. 3 - RELs zeroed per BSList