Recent Log Entries

The following cavities have been GSET 0: 2L14-7

Log Number: 3893066Logbook(s): Tags: Body: 

The following cavities have been GSET 0:
2L14-7
Username: kiarra
Date/Time: 08-16-21_05:52:46
RF Status: Bad
Tuner Status: Good
Comment: GSET 0 - stepped off +100k - Repeated Manual Arc Test Faults
Special Instructions:

2S-2E re-quad centered and Steering Optimization

Log Number: 3893064Logbook(s): Entry Makers: bfreemanBody: 

Carefully quad centered in 2S and 2E. Nothing really crazy was observed. I was able to then repeat the Spreader Optimization. I was not very far off from where the crew determined a week ago (See Linked entry).

Fig 1 - are the SOFs compared to where I found them. I did also set the 2S00 BPM after this. There were some other 1+ mm changes made. I also did not change the S02 and S03 X values, these are set using a slightly different procedure.

Fig 2-Are the dipole settings that I settled on.

Fig 5 - I also used the Re-Inj trims to help in 3L.
Fig 3 and 4 are the orbits.

Autolog save

Log Number: 3893063Logbook(s): Tags: Body: saver ran from opsl632

Saved: bfreeman 08-16-21 05:35:14 {A:1 B:2 C:5 E:910 A=BS B=BS C=Tune D=BS 0R08=0.00 5R dump in. A B C dump(s) in.

Fopt

Log Number: 3893062Logbook(s): Tags: Body: Fopt 7.6.2 completed successfully. The runtime settings include a sample count of 15, a minimum current of 4, and an operating regime of Standard with Excitation in 1S Region. The corrector and RF kicks applied were 1.28778 and 1.28778 volts respectively. The max. amplitude setting was 1 millimeters. The files for this run were saved in the directory /cs/opshome/hlapps/optics/diforb/21aug160525. The X and Y stability of the machine during the run was 0.156585 and 0.0631088 (mm) respectively.

Fopt

Log Number: 3893061Logbook(s): Tags: Body: Fopt 7.6.2 completed successfully. The runtime settings include a sample count of 15, a minimum current of 4, and an operating regime of Standard with Excitation in 1S Region. The corrector and RF kicks applied were 1.28778 and 1.28778 volts respectively. The max. amplitude setting was 1 millimeters. The files for this run were saved in the directory /cs/opshome/hlapps/optics/diforb/21aug160510. The X and Y stability of the machine during the run was 0.182555 and 0.0668993 (mm) respectively.

Fopt

Log Number: 3893059Logbook(s): Tags: Body: Fopt 7.6.2 completed successfully. The runtime settings include a sample count of 15, a minimum current of 4, and an operating regime of Standard with Excitation in 1S Region. The corrector and RF kicks applied were 1.28778 and 1.28778 volts respectively. The max. amplitude setting was 1 millimeters. The files for this run were saved in the directory /cs/opshome/hlapps/optics/diforb/21aug160436. The X and Y stability of the machine during the run was 0.125672 and 0.0626307 (mm) respectively.

Fopt failure

Log Number: 3893058Logbook(s): Tags: Body: Fopt 7.6.2 failed with the following diagnostic:
Current too low [3.99]GUI's Log PageFopt Progress Log
04:36:45 Starting Fopt
04:36:45 Fetching current and energies
04:36:45 Current too low [3.99]

Fopt

Log Number: 3893057Logbook(s): Tags: Body: Fopt 7.6.2 completed successfully. The runtime settings include a sample count of 15, a minimum current of 4, and an operating regime of Standard with Excitation in 1S Region. The corrector and RF kicks applied were 1.28778 and 1.28778 volts respectively. The max. amplitude setting was 1 millimeters. The files for this run were saved in the directory /cs/opshome/hlapps/optics/diforb/21aug160429. The X and Y stability of the machine during the run was 0.218143 and 0.0993329 (mm) respectively.

Fopt failure

Log Number: 3893056Logbook(s): Tags: Body: Fopt 7.6.2 failed with the following diagnostic:
GUI's Log PageFopt Progress Log
04:28:42 Starting Fopt
04:28:42 Fetching current and energies
04:28:42 Extracting BPM information from CED
04:28:42 Number of BPMs detected: 361
04:28:42 Determining status of Halls
04:28:42 Suspending Energy Locks
04:28:42 Failed to suspend Energy Locks
04:28:42 Suspending Orbit Locks
04:28:42 Programming the function generator
04:28:43 Enabling kick control hardware
04:28:43 Turning off Fast Feedback to A & C

Fopt failure

Log Number: 3893055Logbook(s): Tags: Body: Fopt 7.6.2 failed with the following diagnostic:
GUI's Log PageFopt Progress Log
04:27:55 Starting Fopt
04:27:55 Fetching current and energies
04:27:55 Extracting BPM information from CED
04:27:56 Number of BPMs detected: 361
04:27:56 Determining status of Halls
04:27:56 Suspending Energy Locks
04:27:56 Failed to suspend Energy Locks
04:27:56 Suspending Orbit Locks
04:27:56 Programming the function generator
04:27:56 Enabling kick control hardware
04:27:56 Turning off Fast Feedback to A & C

Fopt

Log Number: 3893053Logbook(s): Tags: Body: Fopt 7.6.2 completed successfully. The runtime settings include a sample count of 15, a minimum current of 4, and an operating regime of Standard with Excitation in 1S Region. The corrector and RF kicks applied were 1.28778 and 1.28778 volts respectively. The max. amplitude setting was 1 millimeters. The files for this run were saved in the directory /cs/opshome/hlapps/optics/diforb/21aug160350. The X and Y stability of the machine during the run was 0.158116 and 0.114578 (mm) respectively.

Autolog save

Log Number: 3893052Logbook(s): Tags: Body: saver ran from opsl632

Saved: bfreeman 08-16-21 03:53:22 {A:1 B:2 C:5 E:910 A=BS B=BS C=Tune D=BS 0R08=4.23 5R dump in. A B C dump(s) in. After 2S Quad Centering and Shunt Optimization} { } ALL

Comments:

dogCalc Vpro download

Log Number: 3893050Logbook(s): Tags: Body: dogCalc Vpro download

CED workspace: OPS
CED login_key: pro


CHANNELNEW VALUEOLD VALUEMDOG2E.BDL468006.9573475058.6910MBW2E01.BDL-468121.9573-475173.6910MDOG3E.BDL664436.0951653138.6252MBW3E01.BDL-659494.0951-648196.6252

dogCalc Vpro download

Log Number: 3893048Logbook(s): Tags: Body: dogCalc Vpro download

CED workspace: OPS
CED login_key: pro


CHANNELNEW VALUEOLD VALUEMDOG1E.BDL249973.2224225029.3648MBW1E01.BDL-249881.2224-224937.3648MDOG2E.BDL475058.6910474327.8987MBW2E01.BDL-475173.6910-474442.8987MDOG3E.BDL653138.6252654165.8020MBW3E01.BDL-648196.6252-649223.8020

dogCalc Vpro download

Log Number: 3893047Logbook(s): Tags: Body: dogCalc Vpro download

CED workspace: OPS
CED login_key: pro


CHANNELNEW VALUEOLD VALUEMDOG2E.BDL474327.8987482514.4193MBW2E01.BDL-474442.8987-482629.4193MDOG3E.BDL654165.8020634087.5253MBW3E01.BDL-649223.8020-629145.5253

dogCalc Vpro download

Log Number: 3893046Logbook(s): Tags: Body: dogCalc Vpro download

CED workspace: OPS
CED login_key: pro


CHANNELNEW VALUEOLD VALUEMDOG2E.BDL482514.4193427712.1656MBW2E01.BDL-482629.4193-427827.1656MDOG3E.BDL634087.5253596544.3702MBW3E01.BDL-629145.5253-591602.3702

HYST AREA 6-2-2 Cycles Magnets

Log Number: 3893045Logbook(s): Body: 

HYST AREA Version 6-2-2 has successfully cycled the following:

Area.Arcs.Arc2.Spreader
Area.Arcs.Arc2.Arc
Area.Arcs.Arc2.Recombiner
Area.Arcs.Arc2.Extraction
Area.Arcs.Arc4.Spreader
Area.Arcs.Arc4.Arc
Area.Arcs.Arc4.Recombiner
Area.Arcs.Arc4.Extraction

Total Time: 3.233 mins