iCalibrate: Hall A

Log Number: 4065664Logbook(s): Body: Calibration ParametersHall:ATarget: Carbon OpticsPass: 2Note: Raster @ 4.3mmCalibrated On:2022-Oct-16 13:07Calibrated By: bschaumlFile:A-2022-10-16_1307_Carbon_Optics_Pass-2.hcdIon ChamberExisting Setpoing (rads/hr)New Setpoint (rads/hr)Com

Hall A -> 5 uA on Carbon Optics

Log Number: 4065660Logbook(s): Entry Makers: bschaumlBody: 

Hall is authorized up to 60 uA CW.
Per Operational Restrictions, with the Carbon Optics Target, the hall may receive up to 60 uA CW with raster A on at V=1.3409 & H=1.2068.
Max Juice is set to 7 uA
Raster A is on at V=1.3409 & H=1.2068.
Cooling Jets are OK.
Ramp Protection is ON
Ion Chambers are set using the "Carbon Optics" calibration for 5uA with a 30% margin.

1L10-6 POff Optimization

Log Number: 4065659Logbook(s): Body: 

Channels: R1A6POFFr

Has been particularly trippy as we send 60uA to Hall C. Hoping this calms it down some. Otherwise, may end up de-rating.

iCalibrate: Hall A

Log Number: 4065658Logbook(s): Body: Calibration ParametersHall:ATarget: Carbon OpticsPass: 2Note: Raster @ 4.3mmCalibrated On:2022-Oct-16 13:07Calibrated By: bschaumlFile:A-2022-10-16_1307_Carbon_Optics_Pass-2.hcdIon ChamberExisting Setpoing (rads/hr)New Setpoint (rads/hr)Com

Autolog save

Log Number: 4065644Logbook(s): Tags: Body: saver ran from opsl06

Saved: bschauml 10-21-22 21:32:01 {A:2 B:5 C:5 E:1047 A=CW B=CW C=CW D=CW 0R08=65.01 No dumps in.

Autolog save

Log Number: 4065643Logbook(s): Tags: Body: saver ran from opsl06

Saved: bschauml 10-21-22 21:29:40 {A:2 B:5 C:5 E:1047 A=CW B=CW C=CW D=CW 0R08=66.27 No dumps in.

guidance for adjusting Hall A beam envelope

Log Number: 4065620Logbook(s): Entry Makers: roblinBody: 

The Hall A optics are such that the last six quads are off . As a consequence C19 and C20 quads can be used to adjust the beam envelope.
As a general rule, you should find that for both X and Y, size at H04B > size at H04A, that is the beam is diverging (on purpose).
If the Hall A staff tells you that beam is :

too big in X:
reduce the amplitude of MQR1C20 (less positive)
too big in Y:
reduce the amplitude of MQR1C19 (make it less negative)

if its too small do the opposite.

Alternatively , you can also use matching quads ike 1C08.

Hall A -> 5 uA on Carbon Hole

Log Number: 4065618Logbook(s): Entry Makers: bschaumlBody: 

Hall is authorized up to 60 uA CW.
Per Operational Restrictions, with the Carbon Hole Target, the hall may receive up to 60 uA CW with raster A on at V=1.3409 & H=1.2068.
Max Juice is set to 7 uA
Raster A is on at V=1.3409 & H=1.2068.
Cooling Jets are OK.
Ramp Protection is ON
Ion Chambers are set using the "Carbon Hole" calibration for 5uA with a 30% margin.

iCalibrate: Hall A

Log Number: 4065617Logbook(s): Body: Calibration ParametersHall:ATarget: Carbon HolePass: 2Note: 4.3mm Diameter RasterCalibrated On:2022-Oct-16 13:49Calibrated By: bschaumlFile:A-2022-10-16_1349_Carbon_Hole_Pass-2.hcdIon ChamberExisting Setpoing (rads/hr)New Setpoint (rads/hr)