Recent Log Entries

LERF FL02 cryomodule insulating vacuum

Log Number: 4130495Logbook(s): Body: 

Insulating vacuum much cooler than vault ambient temperature. insulating vacuum turbo pump / rough pump appears to be okay. The pump doesn't
have a working pressure gauge. Decided to install another turbo pump with a working gauge at the downstream isolation valve. Pressures 7e-4
with both pumps open to the insulating vacuum. Note. 7e-4 while at 4k.
Also. Beamline vacuum came up 2 decades transitioning to 4k.

FSD Masking Tool: Successful System Masking for: Vacuum

Log Number: 4130490Logbook(s): Tags: Body: System Masking for: Vacuum
User: anthony
Areas: SouthLinac

Vacuum Devices:
VBV2L01B
VFV2L02
VBV2L02A
VBV2L02B
VBV2L03A
VBV2L03B
VBV2L04A
VBV2L04B
VBV2L05A
VBV2L05B
VBV2L06A
VBV2L06B
VBV2L07A
VBV2L07B
VBV2L08A
VBV2L08B
VBV2L09A
VBV2L09B
VBV2L10A
VBV2L10B
VBV2L11A
VBV2L11B
VBV2L12A
VBV2L12B
VBV2L13A
VBV2L13B
VBV2L14A
VBV2L14B
VBV2L15A
VBV2L15B
VBV2L16A
VBV2L16B
VBV2L17A
VBV2L17B
VBV2L18A
VBV2L18B
VBV2L19A
VBV2L19B
VBV2L20A
VBV2L20B
VBV2L21A
VBV2L21B
VBV2L

iocsoftradtst restored

Log Number: 4130488Logbook(s): Tags: Body: restorelib 2.4 Target restore date was 2023-02-07 13:56:04 The output from the myRestore execution was as follows: iocsoftradtst systemEnum@2023-02-07 13:56 2(2) restored Execute: /usr/csite/certified/bin/ced2Epics -ced ced -A -s -i iocsoftradtst (success) Procedure return status: Success

Follow-up Re: SL trip due to LERF

Log Number: 4130474Logbook(s): Body: 

FL02 seemed to pressurized before the trip (CPIFL0260). The JT valve opened even though the liquid level was slightly above setpoint.

SL trip due to LERF

Log Number: 4130472Logbook(s): Entry Makers: creelBody: 

SL trip stemmed from problems at LERF.
We are investigating with SRF.

CREW CHIEF SIGN IN

Log Number: 4130471Logbook(s): Body: 
THOMAS JEFFERSON NATIONAL ACCELERATOR FACILITY
ACCELERATOR OPERATIONS CREW CHIEF SIGN IN FORM

Date : 02-13-23
Time : 16:37:50
Day : Monday
Shift : Swing

Crew Chief : Freeman
Program Deputy: Letta
Team : -
Arm : Anthony
Designated SSO: Schaumloffel
LERF Operator:
Operators : Anthony, Schaumloffel, Howard

This stamp certifies that the above Crew Chief has read/reviewed/received the following:

Operator In Training SIGN IN

Log Number: 4130463Logbook(s): Body:  ACCELERATOR OPERATOR IN TRAINING SIGN IN FORM OPERATOR:    Howard
DATE:           02/13/2023
SHIFT:             Swing
MENTOR:         Merz

The operator has read the following:

Operator SIGN IN

Log Number: 4130452Logbook(s): Body:  ACCELERATOR OPERATOR SIGN IN FORM OPERATOR:    Schaumloffel
DATE:             02/13/2023
SHIFT:               Swing

The operator has read the following:

1L20-3 OLT

Log Number: 4130453Logbook(s): Entry Makers: michaelmBody: 

TDETA 17 degrees off; found by smartRAT

iCalibrate: Hall A

Log Number: 4130450Logbook(s): Body: Calibration ParametersHall:ATarget: PolHe3Pass: 4Note: File generated from archiverCalibrated On:2023-Jan-15 17:25Calibrated By: bfreemanFile:A-2023-01-15_1725_PolHe3_Pass-4_archiver_generated.hcdIon ChamberExisting Setpoing (rads/hr)New Setpoint (rads/hr)

Operator SIGN IN

Log Number: 4130448Logbook(s): Body:  ACCELERATOR OPERATOR SIGN IN FORM OPERATOR:    Anthony
DATE:             02/13/2023
SHIFT:               Swing

The operator has read the following:
  • ELOG
  • PD Shift Plan
  • Radiation Surveys for PSS Segments in Controlled Access
  • PSS Log

2L26 TDOFFs adjusted

Log Number: 4130447Logbook(s): Entry Makers: michaelmBody: 

Fig. 1/2 round 1 adjustment
Fig. 3 Round 2 adjustment
Fig. 4/5 after

2L18-5 OLT

Log Number: 4130442Logbook(s): Entry Makers: michaelmBody: 

Wobbly gradient in smartRAT